SE-MS0CC
DownloadRequest a quote
SE-MS0CC Contact Microwave Moisture Analyzer
Measuring method :
Material thickness :
Data refresh rate :
Moisture measuring range :
Signal output :
Collection
Request Test
Specifications
Dimensions
Circuit diagram
Accessories
Applications
Customs data
Base Features
Measuring methodContact
Material thickness70mm~100mm
Electric Data
Operating voltage10V~30V DC (12V DC recommended)
Power consumption≤4W
Data refresh rate35/s
Measuring frequency1000 times/1s
Moisture measuring range0~30%
Moisture measuring accuracy + 0.5% (9-point calibration + 0.2%)
Signal outputRS485/Ethernet (select one) , 4-20mA (1 channel)
CommunicationRS232 remote calibration and 1-channel upgrade.
External input1 channel digital input
EMCEN 61326-1
Based on normEN 61010-1
Temperature measuring-20℃~70℃
Environmental Condition
Enclosure ratingProbe: IP67, Host: IP55
Operating temperatureHost: -20℃~85℃; Probe: -20℃~130℃
Storage temperature-30℃~95℃ (No Freezing)
Operating humidity0~85% RH (No Condensation)
Machine Data
CableBetween main unit and microwave probe<1.5m RF cable; Between main unit and ultrasonic sensor: 2m armored cable
Screen size3.2-inch touchscreen
Microwave probe materialBody: SUS304; Faceplate: Wear-resistant ceramic panel
Microwave probe sizeDiameter: 102 mm; Length: 58 mm
InstallationThe sensor must be placed in the material flow. A 76mm hole needs to be left in the chute for the sensor. Secure it with an M4 screw.
Catalogue
CAD Data
Manuals
WhatsApp
+86 18188641602
WhatsApp
Message
(086) 4008856656