Safety door lock (AR1、AR2、AR3、AR5、AR10 Series)
Safety door lock (AR1、AR2、AR3、AR5、AR10 Series)
AQMS
SelectionModelsDownloadRequest a quote
Selection
Safety door lock (AR1、AR2、AR3、AR5、AR10 Series)
AR10
AR5
AR1
AR2
AR3
->
AR10
Models
AR10 Series
Image
Safety door lock AR10 Series
Working principle
Electromechanical type
Housing
square
Switching principle
Slow-acting switching element
Locking force
1300N
Contact spacing
2x2mm or more
Forced break force
Minimum 60N
Force break line pre-stroke
More than 10mm
Speed of operation
0.1m~0.5m/s
Frequency of operation allowed
Max. 30 operations/min
Indicator light
Green, orange optional
Type of use
AC-15/DC-13
Rated operating voltage
240V/24V
Rated operating current
200mA
Contact resistance
Under 25mΩ
Rated insulation voltage
300V
Insulation Resistance
Less than 100mΩ
Condition short circuit Current
100A
Level of protection against electric shock
Class II (double insulation)
Short circuit protection
10A,250V requires quick-break type fuse
Working environment temperature
-10 ° C to + 55 ° C without icing
Working environment humidity
Below 95% RH
Pulse withstand voltage
2.5 KV
Pollution level
3 (EN60947-5-1)
Vibration Resistance
10 to 55Hz double amplitude 1.5mm
Impact Resistance: Durability
1000m/s²
Impact Resistance: misaction
300m/s²
Protection level
IP67
Connection type
Cable
Life: Mechanical
More than 1 million times
Life: Electrical
More than 150,000 times
Size
36x23x12mm
Material
PA66 flame retardant
Weight
about 57g
AR10
->
AR5
Models
AR5 Series
Image
Safety door lock AR5 Series
Working principle
Electromechanical type
Housing
square
Switching principle
Slow-acting switching element
Locking force
2000N
Contact spacing
2x2mm or more
Forced break force
Minimum 60N
Force break line pre-stroke
More than 10mm
Speed of operation
0.1m~0.5m/s
Frequency of operation allowed
Max. 30 operations/min
Indicator light
Green, orange optional
Type of use
AC-15/DC-13
Rated operating voltage
240V/24V
Rated operating current
200mA
Contact resistance
Under 25mΩ
Rated insulation voltage
300V
Insulation Resistance
Less than 100mΩ
Condition short circuit Current
100A
Level of protection against electric shock
Class II (double insulation)
Short circuit protection
10A,250V requires quick-break type fuse
Working environment temperature
-10 ° C to + 55 ° C without icing
Working environment humidity
Below 95% RH
Pulse withstand voltage
2.5 KV
Pollution level
3 (EN60947-5-1)
Vibration Resistance
10 to 55Hz double amplitude 1.5mm
Impact Resistance: Durability
1000m/s²
Impact Resistance: misaction
300m/s²
Protection level
IP67
Connection type
E:M12 connector with pigtail; Blank:wirs
Life: Mechanical
More than 1 million times
Life: Electrical
More than 150,000 times
Size
29.7x29.8x125.75mm
Material
PA66 flame retardant
Weight
about470g
AR5
->
AR1
Models
AR1 Series
Image
Safety door lock AR1 Series
Working principle
Electromechanical type
Housing
square
Switching principle
Slow-acting switching element
Locking force
1300N
Contact spacing
2x2mm or more
Forced break force
Standard type: min 60N; Strong tension type: min. 80N
Force break line pre-stroke
More than 10mm
Speed of operation
0.1m~0.5m/s
Frequency of operation allowed
Max. 20 operations/min
Indicator light
Green, orange optional
Type of use
AC-15/DC-13
Rated operating voltage
240V/24V
Rated operating current
3A/2A
Contact resistance
Under 25mΩ
Rated insulation voltage
300V
Insulation Resistance
less than 100mΩ (under 500VDC)
Condition short circuit Current
100A
Level of protection against electric shock
Class II (double insulation)
Short circuit protection
10A,250V requires quick-break type fuse
Working environment temperature
-10℃ ~ + 70℃ no icing
Working environment humidity
85% RH
Pulse withstand voltage
2.5 KV
Pollution level
3 (EN60947-5-1)
Vibration Resistance
10 to 55Hz double amplitude 1.5mm
Impact Resistance: Durability
1000m/s²
Impact Resistance: misaction
300m/s²
Protection level
IP67
Connection type
P: Pg13.5 (terminal type) M: M20 (terminal type) 2M: standard wire extraction type (2m) 2ME: bending wire extraction type (2m)
Life: Mechanical
More than 1 million times
Life: Electrical
More than 150,000 times
Size
29.84x30.1x96mm
Material
PA66 flame retardant
Weight
About 96.5g
AR1
->
AR2
Models
AR2 Series
Image
Safety door lock AR2 Series
Working principle
Electromechanical type
Housing
square
Switching principle
Slow-acting switching element
Locking force
1300N
Contact spacing
2x2mm or more
Forced break force
Minimum 60N
Force break line pre-stroke
More than 10mm
Speed of operation
0.1m~0.5m/s
Frequency of operation allowed
Max. 30 operations/min
Indicator light
Green, orange optional
Type of use
AC-15/DC-13
Rated operating voltage
240V/24V
Rated operating current
3A/2A
Contact resistance
Under 25mΩ
Rated insulation voltage
300V
Insulation Resistance
Less than 100mΩ
Condition short circuit Current
100A
Level of protection against electric shock
Class II (double insulation)
Short circuit protection
10A,250V requires quick-break type fuse
Working environment temperature
-10 ° C to + 55 ° C without icing
Working environment humidity
Below 95% RH
Pulse withstand voltage
2.5 KV
Pollution level
3 (EN60947-5-1)
Vibration Resistance
10 to 55Hz double amplitude 1.5mm
Impact Resistance: Durability
1000m/s²
Impact Resistance: misaction
300m/s²
Protection level
IP67
Connection type
M: M20 (terminal type
Life: Mechanical
More than 1 million times
Life: Electrical
More than 150,000 times
Size
88x34.3x108mm
Material
PA66 flame retardant
Weight
About 370.6g
AR2
->
AR3
Models
AR3 Series
Image
Safety door lock AR3 Series
Working principle
Electromechanical type
Housing
square
Switching principle
Slow-acting switching element
Locking force
1300N
Contact spacing
2x2mm or more
Forced break force
Minimum 60N
Force break line pre-stroke
More than 10mm
Speed of operation
0.1m~0.5m/s
Frequency of operation allowed
Max. 30 operations/min
Indicator light
green
Type of use
AC-15/DC-13
Rated operating voltage
240V/24V
Rated operating current
3A/2A
Contact resistance
Under 25mΩ
Rated insulation voltage
300V
Insulation Resistance
Less than 100mΩ
Condition short circuit Current
100A
Level of protection against electric shock
Class II (double insulation)
Short circuit protection
10A,250V requires quick-break type fuse
Working environment temperature
-10 ° C to + 55 ° C without icing
Working environment humidity
Below 95% RH
Pulse withstand voltage
2.5 KV
Pollution level
3 (EN60947-5-1)
Vibration Resistance
10 to 55Hz double amplitude 1.5mm
Impact Resistance: Durability
1000m/s²
Impact Resistance: misaction
300m/s²
Protection level
IP67
Connection type
P: Pg13.5 (terminal type) M: M20 (terminal type)
Life: Mechanical
More than 1 million times
Life: Electrical
500,000 + times (AC240V 3A, resistive load)
Size
35x36x165mm
Material
PA66 flame retardant
Weight
About 253.4g
AR3