PT-10ML Wide Area Head Fiber Units
Sensing method :
Fiber size :
Min. sensing object diameter :
Core structure :
Housing :
Collection
Request Test
Specifications
Dimensions
Circuit diagram
Accessories
Applications
Customs data
Base Features
Working principleFiber
Sensing methodThrough-beam
Housing-
Length of convex tube-
Fiber sizeRectangular
Length of fiber2000mm
Diameter of fiberØ0.25mm
Fiber arrangementOptical grating
Core structureEmitter: 16; Receiver: 16
Integrated lens-
Min. sensing object diameterØ3.0mm
Machine Data
Operating temperature-
Bending radius5mm
Can be cutYes
Housing materialAluminum + PE
AccessoriesScrew, bracket, screwdriver
PE1 Amplifier Detection Distance Reference (White Paper) >
1-HS(Threshold: 16)340mm
2-FS(Threshold: 20)510mm
3-ST(Threshold: 30)890mm
4-LG(Threshold: 40)980mm
5-PL(Threshold: 50)1310mm
PE2 Amplifier Detection Distance Reference (White Paper) >
1-HS(Threshold: 7)100mm
2-FS(Threshold: 7)130mm
3-ST(Threshold: 19)840mm
4-LG(Threshold: 19)1330mm
5-PL(Threshold: 19)2010mm
6-SU(Threshold: 19)2380mm
7-UL(Threshold: 19)3600mm
PC2 Amplifier Detection Distance Reference (White Paper) >
1-HS(Threshold: 20)210mm
2-FS(Threshold: 19)690mm
3-ST(Threshold: 15)1280mm
4-LG(Threshold: 16)1670mm
5-PL(Threshold: 23)2340mm
6-SU(Threshold: 28)3600mm
7-UL(Threshold: 27)3600mm
PC3 Amplifier Detection Distance Reference (White Paper) >
1-HS(Threshold: 18)90mm
2-FS(Threshold: 8)310mm