Navigational Lidar
Navigational Lidar
DHXJGLD
SelectionModelsDownloadRequest a quote
Navigation Laser Lidar AS-100C
Navigation Laser Lidar AS-100C
  • Detection Range:0.2m~100m
  • Size:110*96.5*71.5(mm)
  • Laser Safety Level:Class I (GB7247.1-2012,Eye Safety)
  • Laser Spot Divergence Angle:2.0(H)×8.0(V)m rad
  • Scanning Angle Range:360°
Collection
Request a sample
Technical specifications
Size structure
Circuit diagram
Accessories
Applications
Customs data
ModelAS-100C
Light SourceInfrared laser(905nm)
Laser Safety LevelClass I (GB7247.1-2012,Eye Safety)
Laser Spot Divergence Angle2.0(H)×8.0(V)m rad
Scanning Angle Range360°
Scanning Frequency10Hz/20Hz
Scanning Angle Resolution0.05°/0.1°
Equipment Self-InspectionContent: light transmission cover dirty/blocked/high temperature/low temperature
Working Voltage9V~30V DC
Power Consumption5W@DC 24V
Weight0.7kg
Size110*96.5*71.5(mm)
Static Electricity6KV(GB/T 17626.2~2006,Class 3)
Electrical Fast Transient1KV(GB/T 17626.4~2008,Class 2)
Electromagnetic Field Radiation ImmunityGB/T 17626.3~2006,Class 2
Insulation Resistance1MΩ(GB16796~2009.5.4.4)
Anti-surgeGB/T17626.5-2008; Power interface: 1.2/50μs,2KV/1KA(Class 3); Ethernet interface: 10/700μs,1KV/25A(Class 2); I/O interface: 1.5/50μs,0.5KV/0.25KA(Class 1)
Vibration ResistanceGB/T 2423.10
Working Temperature-10℃~+50℃
Ambient Illuminance≤80,000Lux
Laser Spot Outlet Aperture10mm
Detection Range0.2m~100m
RSSI Detection Range3%~1000%(Reflctor)
10% Reflectivity Range20m
Environment It is resistant to sunlight,dirt and smoke penetration,and can be used under non-rainfall conditions
Measuring Data Composite data (distance+RSSI)
Measuring Error System Error (typical value)Distance measurement: 25mm(1m~20m)/40mm(20m~50m); RSSI measurement: 2%(1m~20m)/4%(20m~50m)
measuring Statistical Error(1σ)Distance measurement: 10mm(1m~20m)/20mm(20m~50m); RSSI measurement: 1%(1m~20m)/2%(20m~50m)
EthernetSpeed: 10/100 Mbps; Function: equipment configuration/measurement data output
Input EndQuantity: 3; Type: level input (vs. general input common ground "GND IN"); High level range: 9V – 30V DC; Low level range: 0V – 0.7V DC; Preset function: power saving and life extension control (IN2/IN3),effective level: high level
Output EndQuantity: 3; Type: PNP switch output (vs. positive end of power supply); Power-on status: off; Preset function: equipment ready (OUT),effective status: ON
IndicatorQuantity: 4; Definition: PWR: power indicator; LNK: Ethernet indicator; ERR: working fault indicator; HTR: normal measurement indicator
Protection DegreeIP65(GB4208~2008)
Dielectric Strength0.5KV(GB16796~2009.5.4.3)
ImpactGB/T 2423.5
Single Impact15g,11ms
Continuous Impact10g,16ms
Frequency Range10Hz~150Hz
Range5g
Ambient Humidity93%,+40℃,2h(GB/T 2423.3)
Storing Temperature-30℃~+70℃

Contact usIf you need to purchase products, please feel free to contact us for more detail

Contact Information List